Open Access
Table 1
Goal sheet of adaptive plan.
The ROIs | ROIs Property | Clinical Goal | Priority | |
---|---|---|---|---|
PCTV | PTV | The Prescription Dose | 50 Gy | 2 |
The Min Dose | ≥50.50 Gy | 1 | ||
The Max Dose | ≤54 Gy | 1 | ||
SpinalCord | Organ | The Max Dose | ≤45 Gy | 1 |
SpinalCord03 mm | Organ | The Maximum Dose | ≤50 Gy | 1 |
Esophagus | The Max Dose | ≤63 Gy | 2 | |
The Mean Dose | ≤30 Gy | 2 | ||
Lungs | Organ | The volume at dose | V20 Gy ≤ 30% | 1 |
Organ | The volume at dose | V30 Gy ≤ 20% | 1 | |
Organ | The volume at dose | V5 Gy ≤ 60% | 1 | |
Heart | Organ | The Mean Dose | ≤20 Gy | 2 |